You are currently viewing How to calculate revised Cable Extension length for Prestressing

How to calculate revised Cable Extension length for Prestressing

Stressing Calculation for Pre Stress concrete 

Required details Revised Extension for cable length :
 As per Design :

  1. Diameter of strands
  2. Area of Strand
  3. Modulus of Elasticity
  4. Design Extension for Cable
As per Third party Result or as per Practical :
  1. Diameter of strands
  2. Area of Strand
  3. Modulus of Elasticity

Other Requird data :

  1. Designed jacking Force
  2. Ram Area of Jack
  3. Jack Efficiency

Calculation Revised Extension for cable :

Modify Pressure = (Jacking force x Design jack efficiency / Jack ram Area x Actual efficiency )
Allowable Toterance = +- 5 %
Revised Extension for cable = Design Extention x (design area of strand / Actual Area of strands ) x (Design Modulus of Elasticity / Modulus of Elasticity as per Test )
Allowable Toterance = +- 5 %